The insulated wire weight data is only indicative and can vary from that given here.
Electrical wire diameter with insulation.
These are commonly used awg sizes with concentric strandings perfectly round geometric configuration.
If in doubt measure the actual material with a micrometer or us a gauge plate as illustrated at right.
The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient air temperature of 30 c 86 f.
Wire size is measured by the american wire gauge awg system.
Common sizes include 14 12 10 8 6 and 2 gauge wire.
Wire cross sectional area calculations.
You need to know the finished diameter of an insulated wire you must consult the manufacturer concerned as all manufacturers differ on this factor.
The n gauge wire diameter d n in millimeters mm is equal to 0 127mm times 92 raised to the power of 36 minus gauge number n divided by 39.
D n mm 0 127 mm 92 36 n 39.
The smaller the awg number the larger the wire and generally speaking the more current the wire can carry without overheating.
In the wire size table below give the typical diameter of 14 copper wire as 2 05 to 2 32 mm or about 0 081 0 092 inches.
The actual wire diameter of 14 copper wire can vary among manufacturers and wire types.
Insulation select the thermal rating of the insulation on the wire.
National electrical code table 310 15 b 16 17.
Typical outside diameter of insulation on 600v industrial wire thhn thwn or thwn 2 90c 75c 600 volt pvc insulation with nylon outer jacket wire size stranding.
Many other special sizes with bunched strands are also available.
Wire size relates to the diameter of the metal conductor of the wire excluding any insulation.
24 awg 0 059 1 5 0 088 2 2 0 020 0 5 0 024 0 6 22 awg 0 066 1 7 0 094 2 4 0 025 0 6 0 031 0 8 20 awg 0 071 1 8 0 101 2 6 0 032 0 8 0 038 1 0 18 awg 0 084 2 1 0 111 2 8 0 040 1 0 0 049 1 2.
This wire size calculator will calculate the appropriate wire gauge for a circuit based on amps voltage distance and load.
The n gauge wire s cross sercional area a n in kilo circular mils kcmil is equal to 1000 times the square wire diameter d in inches in.
Mm size with thw thhw tw insulation with tfn thhn thwn insulation uninsulated conductors range min.
Approximate wire outside diameter in.
Please ask for the size of your interest.
Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductors in other words the smaller the wire gauge number the larger the wire diameter.
Some ideas for using the.